How to do a hard reset at NanoStation m2?

$
0
0

If you have a problem with Ubiquiti NanoStation M2 or PicoStation m2, bullet, rocket, loco m2 or another model on this segment there are 2 ways to do a hard reset to factory settings.

The first way to reset Nanostation m2:

  • Connect your M2 to pc or notebook
  • Open your browser and put Nanostation m2 default IP: 192.168.1.20 or another one you set before.
  • Enter login and pass (by default ubnt)
  • Choose “SYSTEM” at the menu
  • Press “Reset to Default“.
  • Then just wait.

The second way

  1. We recommend doing it when you forgot your password or can’t connect to Nanostation via WEB.
  2. To do it please connect it to pc or notebook and turn it on.
  3. Then you will need to press “Reset” near the main LAN port and wait 8-15 seconds.
  4. When done you will see all indications lamps will blink a few times.

On some devices the reset button on POE (see pic):

nanostation m2 hard reset

reset button Poe Nanostation

Sometimes after resetting user can’t connect to Nanostation m2 and if you are one of them so maybe this information will help you:

  1. check cable connector (anyway)
  2. Set the LAN IP (ipv4) to 192.168.1.21
    subnet mask 255.255.255.0
    default gateway 192.168.1.20  (where to do it? > connection setting > TCP/IPv4 )

Thanks for your attention. Hope this info will useful for you :)